The figure shows the double shear connection. An axially loaded member is shown bolted to parallel square plates that are anchored to a support on the left. The load on the axially loaded member has a magnitude P and is directed to the right.
 

To understand shear stress in a bolted connection, visualize the failure surface that would be created if the bolts were broken.